Registrations
We now manually approve all new user accounts due to a large influx of spam bots. Accounts are normally approved within 48 hours.
If you need any help with using this Wiki, please ask here: TalkFord.com Wiki Submission Forum
Air Conditioning - Climate Control Self Diagnosis Guide
For more information, visit the Ford Mondeo forum on TalkFord.com, the definitive resource site covering all Fords from the present day to the 1970's.
Overview Guide | |
Ford Model: | Mondeo |
---|---|
Petrol/Diesel: | ???? |
Estimated Cost: | ???? |
Difficulty? | ???? |
How long does this take? | ???? |
Contents
Climate Control Self Diagnosis Guide - Mondeo Mk3
Instructions
Activation of self-diagnosis
With the ignition switched on to position 2, on the E(A)TC module, PRESS the "OFF" and "FOOTWELL" buttons simultaneously very briefly, then PRESS "AUTO" within 1.5 seconds.
The self-diagnosis which then starts lasts a few seconds. An animated display appears in the E(A)TC display during this time. Any faults found are displayed in the form of trouble codes. Example: First of all, "93" flashes for 2 seconds, then "42" flashes for 2 seconds - DTC 9342. If no faults are stored, then all of the segments in the display are actuated.
Diagnosis mode can be stopped at any time by PRESSING any button on the E(A)TC module.
Note: If the "DEFROST" button is pressed to end the diagnosis mode, all DTCs in the fault memory will be deleted!
Fault Codes
B1200 Any button of the air conditioning system Button jammed/stuck
B1242* Air recirculation flap: fault in the circuit Open circuit/short circuit
B1251 Interior temperature sensor: open circuit Check the wire and the sensor
B1253 Interior temperature sensor: short to earth Check the wire and the sensor
B1261 Sun load sensor short to earth Check the wire and the sensor
B1262 Air distribution flap - defrost fault in the Check the wiring; defrost flap circuit positioning motor
B1263 Air distribution flap - centre vents: fault Check the wiring; centre vents in the circuit positioning motor
B1342 Automatic climate control module inoperative The trouble code is set in the event of failure.
B1676 Insufficient battery voltage Battery voltage not in the range 9 - 16V
B2266 Temperature flap: fault in the circuit Check the wiring and the temperature flap positioning motor
B2297 Heater housing outlet sensor: open circuit Check the wiring and the sensor
B2298 Heater housing outlet sensor: short to earth Check the wiring and the sensor
B2308 Interior temperature sensor for the fan Damaged motor or open circuit motor inoperative
B2516 Blower: fault in the circuit Damaged motor or open circuit
Self-test code B1200 / 9200
Description Internal control module fault
Action CLEAR fault memory. If the fault occurs again after a functional test, RENEW the E(A)TC module
Self-test code B1242 / 9242
Description Circuit of heater flap control
Action Go to Pinpoint Test D motor, recirculated air fault
Self-test code B1251 / 9251
Description Open circuit in interior
Action Go to Pinpoint Test M temperature sensor circuit
Self-test code B1253 / 9253
Description Short circuit in interior
Action Go to Pinpoint Test M temperature sensor circuit (short to ground)
Self-test code B1261 / 9261
Description Short circuit in sun load sensor
Action Go to Pinpoint Test L circuit (short to ground)
Self-test code B1262 / 9262
Description Circuit of defrost actuator motor
Action Go to Pinpoint Test E, faulty
Self-test code B1263 / 9263
Description Circuit of dashboard/footwell
Action Go to Pinpoint Test F actuator motor faulty
Self-test code B1342 / 9342
Description Internal control module fault
Action CLEAR fault memory. If the fault occurs again after a functional test, RENEW the E(A)TC module
Self-test code B1676 / 9676
Description Power supply voltage outside
Action CHECK charging system. For further tolerance information Section 414-00 If the charging system is OK, Go to Pinpoint Test J
Self-test code B2266 / A266
Description Air temperature flap positioning
Action Go to Pinpoint Test G motor circuit faulty
Self-test code B2297 / A299
Description Open circuit in the footwell outlet
Action Go to Pinpoint Test H temperature sensor circuit
Self-test code B2298 / A307
Description Short circuit in the footwell
Action Go to Pinpoint Test H outlet temperature sensor circuit(short to ground)
Self-test code A297
Description Open circuit in the dashboard
Action Go to Pinpoint Test I outlet temperature sensor circuit
Self-test code A298
Description Short in the dashboard outlet
Action Go to Pinpoint Test I temperature sensor circuit (short to ground)
Self-test code B2308 / A308
Description Interior temperature sensor blower
Action Go to Pinpoint Test N circuit faulty
Self-test code B2516 / A516
Description Heater blower control module
Action Go to Pinpoint Test K circuit faulty