Registrations

We now manually approve all new user accounts due to a large influx of spam bots. Accounts are normally approved within 48 hours.

If you need any help with using this Wiki, please ask here: TalkFord.com Wiki Submission Forum

Air Conditioning - Climate Control Self Diagnosis Guide

From www.FordWiki.co.uk
Revision as of 12:12, 29 October 2012 by Rob99 (Talk | contribs)

Jump to: navigation, search
The Ford Mondeo hit our roads in 1993, and has consistently been a sales success. Now on its 4th incarnation, it remains a drivers favourite.
For more information, visit the Ford Mondeo forum on TalkFord.com, the definitive resource site covering all Fords from the present day to the 1970's.

Fordwiki infobox.png
Overview Guide
Ford Model: Mondeo
Petrol/Diesel: ????
Estimated Cost: ????
Difficulty? ????
How long does this take? ????

Climate Control Self Diagnosis Guide - Mondeo Mk3

Instructions

Activation of self-diagnosis

With the ignition switched on to position 2, on the E(A)TC module, PRESS the "OFF" and "FOOTWELL" buttons simultaneously very briefly, then PRESS "AUTO" within 1.5 seconds.

The self-diagnosis which then starts lasts a few seconds. An animated display appears in the E(A)TC display during this time. Any faults found are displayed in the form of trouble codes. Example: First of all, "93" flashes for 2 seconds, then "42" flashes for 2 seconds - DTC 9342. If no faults are stored, then all of the segments in the display are actuated.

Diagnosis mode can be stopped at any time by PRESSING any button on the E(A)TC module.

Note: If the "DEFROST" button is pressed to end the diagnosis mode, all DTCs in the fault memory will be deleted!

Fault Codes

B1200 Any button of the air conditioning system Button jammed/stuck

B1242* Air recirculation flap: fault in the circuit Open circuit/short circuit

B1251 Interior temperature sensor: open circuit Check the wire and the sensor

B1253 Interior temperature sensor: short to earth Check the wire and the sensor

B1261 Sun load sensor short to earth Check the wire and the sensor

B1262 Air distribution flap - defrost fault in the Check the wiring; defrost flap circuit positioning motor

B1263 Air distribution flap - centre vents: fault Check the wiring; centre vents in the circuit positioning motor

B1342 Automatic climate control module inoperative The trouble code is set in the event of failure.

B1676 Insufficient battery voltage Battery voltage not in the range 9 - 16V

B2266 Temperature flap: fault in the circuit Check the wiring and the temperature flap positioning motor

B2297 Heater housing outlet sensor: open circuit Check the wiring and the sensor

B2298 Heater housing outlet sensor: short to earth Check the wiring and the sensor

B2308 Interior temperature sensor for the fan Damaged motor or open circuit motor inoperative

B2516 Blower: fault in the circuit Damaged motor or open circuit

Self-test code B1200 / 9200

Description Internal control module fault

Action CLEAR fault memory. If the fault occurs again after a functional test, RENEW the E(A)TC module


Self-test code B1242 / 9242

Description Circuit of heater flap control

Action Go to Pinpoint Test D motor, recirculated air fault


Self-test code B1251 / 9251

Description Open circuit in interior

Action Go to Pinpoint Test M temperature sensor circuit


Self-test code B1253 / 9253

Description Short circuit in interior

Action Go to Pinpoint Test M temperature sensor circuit (short to ground)


Self-test code B1261 / 9261

Description Short circuit in sun load sensor

Action Go to Pinpoint Test L circuit (short to ground)


Self-test code B1262 / 9262

Description Circuit of defrost actuator motor

Action Go to Pinpoint Test E, faulty


Self-test code B1263 / 9263

Description Circuit of dashboard/footwell

Action Go to Pinpoint Test F actuator motor faulty


Self-test code B1342 / 9342

Description Internal control module fault

Action CLEAR fault memory. If the fault occurs again after a functional test, RENEW the E(A)TC module


Self-test code B1676 / 9676

Description Power supply voltage outside

Action CHECK charging system. For further tolerance information Section 414-00 If the charging system is OK, Go to Pinpoint Test J


Self-test code B2266 / A266

Description Air temperature flap positioning

Action Go to Pinpoint Test G motor circuit faulty


Self-test code B2297 / A299

Description Open circuit in the footwell outlet

Action Go to Pinpoint Test H temperature sensor circuit


Self-test code B2298 / A307

Description Short circuit in the footwell

Action Go to Pinpoint Test H outlet temperature sensor circuit(short to ground)


Self-test code A297

Description Open circuit in the dashboard

Action Go to Pinpoint Test I outlet temperature sensor circuit


Self-test code A298

Description Short in the dashboard outlet

Action Go to Pinpoint Test I temperature sensor circuit (short to ground)


Self-test code B2308 / A308

Description Interior temperature sensor blower

Action Go to Pinpoint Test N circuit faulty


Self-test code B2516 / A516

Description Heater blower control module